USAfixTM - Repair Guide (RG) - Master Email RG
- Check for power output on auxillary socket
 Level of Difficulty - HIGH  Estimated Completion Time - 5 minutes
TASKI - ERGODISC 200

Tools Required
Tool 
Volt meter (True RMS capable)

Parts Required


Step Procedure & Parts & Tools
1 PLUG THE UNIT IN. LOCATE THE AUXILLARY SOCKET ON THE BACK OF THE HANDLE. OPEN SPRING LOADED COVER AND INSERT THE LEADS INTO THE PORTS AS SHOWN. (DOESN'T MATTER WHICH LEAD GOES WHERE). SET THE VOLT METER TO AC VOLTAGE. THE VOLT METER SHOULD READ APPROX. 120 VOLTS. IF METER READS 120 VOLTS, POWER TO THE SOCKET IS GOOD.
Volt meter (True RMS capable)